盈彩厅

Guangdong Yuefeng Air Conditioning Mechanical&Electrical Engineering Co., Ltd. Welcome You!

Industrial plant purification and HVAC engineering service provider with 25 years of experience

Grade Ⅲ qualification for electromechanical installation More than 1,000 Quality projects Zero delay

Service hotline:

138-0964-9905

135-2855-1258

Contact yue feng

盈彩厅Guangdong yuefeng air conditioning mechanical and electrical engineering co. LTD

盈彩厅Mobile phone 1:135-2855-1258

盈彩厅Mobile phone 2:135-2855-1258

盈彩厅E-Mai:airzhu@yuefeung.com

Company Address:10 huankeng road, tingshan kengkou village, houjie town, dongguan city

Online message

Cleaning method of drain pipe blockage in central air conditioning engineering

Release time:2019-12-31 Clicks:58

【Abstract】:Central air conditioning engineering has many advantages, such as energy conservation, environmental protection, health and comfort, so it is widely used in factories, factories, office buildings, shopping malls, hotels and other places. But at the same time, because the central air-conditioning system is more sophisticated and complex than the ordinary hanging air-conditioning and cabinet air-conditioning, it is more difficult for the cleaning and maintenance of air-conditioning and troubleshooting. One of the common problems is that the drain pipe of the central air conditioning project is blocked. Today, we will talk about how to deal with this problem.

Central air conditioning engineering has many advantages, such as energy conservation, environmental protection, health and comfort, so it is widely used in factories, factories, office buildings, shopping malls, hotels and other places. But at the same time, because the central air-conditioning system is more sophisticated and complex than the ordinary hanging air-conditioning and cabinet air-conditioning, it is more difficult for the cleaning and maintenance of air-conditioning and troubleshooting. One of the common problems is that the drain pipe of the central air conditioning project is blocked. Today, we will talk about how to deal with this problem.

盈彩厅If the drain pipe of central air conditioning works is blocked, the electric valve and filter shall be removed for cleaning. When the drain pipe is blocked, the most likely cause of the fault is the electric valve and filter at the front of the water inlet, and other parts are less likely to be dirty and blocked; if the drain pipe is blocked in the middle of the coil, it can be solved by air conditioning water recoil or high-pressure water recoil; if not, it can only be solved by welding the elbow and blasting.

When the drain pipe of central air conditioning works is blocked at the filter and electric valve, the filter and electric valve shall be disassembled for flushing to solve the problem; because the inner hole of electric valve is small, and some pipe holes have filter screen, it is easy to cause blocking, especially when there is no filter installed at the front of water inlet.

This article comes from Guangdong Yuefeng air conditioning mechanical and Electrical Engineering Co., Ltd. reprint please indicate the source!For more information about Yuefeng air conditioning electromechanical engineering, please click www.yuefeng.com, 24-hour hotline: 138-0964-9905!

粤丰空调机电工程二维码

盈彩厅 Guangdong yuefeng air conditioning mechanical and electrical engineering co. LTD

contact
    1. The contact:Manager Su
    2. Mobile phone 1:138-0964-9905
    3. Mobile phone 2:135-2855-1258
    4. Fax no.:0769-22404649
    1. Q Q:709161694
    2. E-Mai:airzhu@yuefeung.com
    3. Company Address:10 huankeng road, tingshan kengkou village, houjie town, dongguan city
All rights reserved©  Guangdong yuefeng air conditioning mechanical and electrical engineering co. LTD Technical support: