Yuefeng analyzes the key points of central air conditioning construction for you...

Release time:2019-12-02 Clicks:133

Abstract】:As the saying goes, the central air conditioning is a three-part product, seven part installation. It can be seen that for the central air conditioning project, the installation is very important, which can be said to affect the use effect in the future. So, summed up some key points about the construction of central air conditioning, let's take a look.

As the saying goes, central air conditioning is three products, seven points of installation. Visible to central air conditioning project, the quality of installation is very important, can be said to affect the use effect in the future. Then, summarized about central air conditioning project construction in a few main points, have a look together. 

盈彩厅Central air conditioning engineering: key points of air duct production and operation

盈彩厅1. The angle of tee or cross of circular air duct should be 15-60 degrees, and the allowable deviation of the angle should be less than 1 degree.

盈彩厅2. The connection of each pipe section of air duct shall be detachable, the length of pipe section shall be 1.8-4.0, and the length of welded air duct and spiral air duct can be appropriately lengthened.

盈彩厅3. For the connection of air duct and flange, if the flanging size is 6mm-9mm, the flanging shall be flat without holes.

盈彩厅Central air conditioning engineering: the key points of components manufacturing and operation of UPVC air duct

1. For horizontal installation of air duct, the allowable deviation of levelness shall not be greater than 3m m per m, and the total deviation shall not be greater than 20mm. The air duct shall be installed vertically; the allowable deviation of perpendicularity shall not be greater than 2m m per m, and the total deviation shall not be greater than 20mm.

盈彩厅2. The support crane and bracket shall not be set at the air port, valve inspection port, and the hanger shall not be directly thrown on the flange.

3. The installation direction and position of the fire damper shall be correct, and the fusible parts shall be installed after the system installation.

4. The installation of all kinds of air outlets shall be flat, the position shall be correct, the rotating part shall be flexible, and the connection with air duct shall be firm.

盈彩厅3、 Central air conditioning engineering: key points of manufacturing and installation of air treatment room

盈彩厅1. The assembly of each section of the metal air treatment room shall be flat, firm, tightly connected and in the correct position, and the spray section shall be free of water leakage.

2. The inspection door of the air spray section shall be free of water leakage, the upstream pipe of the condensate shall be smooth, and the condensate shall not overflow.

3. The short water supply and return pipe embedded in the brick and concrete air treatment room shall be welded with square ribs, and the pipe end shall be equipped with flange or screw mouth, with a distance of 100mm-150 mm from the wall of the treatment room.

4. The cooling surface of surface type or heat exchanger shall be clean and complete.

盈彩厅Central air conditioning engineering: key points of muffler manufacture and installation

1. The selection of silencing materials shall meet the requirements of waterproof, anticorrosive and moisture-proof design.

2. The perforated plate of muffler shall be flat, and the arrangement of holes shall be uniform without burr, and the perforation rate shall meet the design requirements.

3. The installation and fixed end of the silencer shall not be loose, and the distance between the silencers shall be uniform.

4. Muffler and silencing bend shall be supported separately, and its weight shall not be borne by air duct.

盈彩厅 Central air conditioning project: key points of dust remover production and installation

盈彩厅1. The allowable deviation of the outer diameter of the precipitator barrel or the outer dimension of the rectangle shall not be greater than 5%, and the inner and outer surfaces shall be flat and smooth with uniform radian.

2. The inlet and outlet of the precipitator shall be straight, and the discharge pipe of the cylinder and LV under the cone shall be coaxial, and the eccentricity shall not be more than 2mm.

3. The installation and removal of dust remover shall be correct, firm and stable. The direction of inlet and outlet must meet the design requirements. The allowable deviation of perpendicularity shall not be greater than 2mm per meter, and the total deviation shall not be greater than 10 mm.

This article comes from Guangdong Yuefeng air conditioning mechanical and Electrical Engineering Co., Ltd. reprint please indicate the source!For more information about Yuefeng air conditioning electromechanical engineering, please click www.yuefeng.com, 24-hour hotline: 138-0964-9905!

Next article: none
粤丰空调机电工程二维码

Guangdong yuefeng air conditioning mechanical and electrical engineering co. LTD

contact
    1. The contact:Manager Su
    2. Mobile phone 1:138-0964-9905
    3. Mobile phone 2:135-2855-1258
    4. Fax no.:0769-22404649
    1. Q Q:709161694
    2. E-Mai:airzhu@yuefeung.com
    3. Company Address:10 huankeng road, tingshan kengkou village, houjie town, dongguan city
All rights reserved©  Guangdong yuefeng air conditioning mechanical and electrical engineering co. LTD Technical support: